FUSE LINK FOR DROP OUT
To protect over current through the electric circuit, one of the solutions is to use universal fuse link to work associated with drop fuse cutout, its principle is to melt and disconnect the circuit when quite high current through the fuse link. The heat from the expulsion of fusible element will burn the fiber liner in the fuse holder to generate gas to distinguish the arc and keep pressure inside insufficiently to explode. Normally, there will be two types which are solid button head and removable button head, some fuse cutout is designed to increase interrupting capacity by using arc-shortening rod with removable button head fuse link type.
APPLICATION Universal fuse links are deployed in all kinds of industry, worldwide. Utilities: electricity production and distribution Industries: electrical service or maintenance Buildings: electrical service or maintenance Laboratories: electrical equipment testing
FEATURE GK Type K and Type T universal fuse links are made in accordance with ANSI/NEMA standards. GK fuse links are designed to carry 150% of their continuous current rating without damage to the fuse link itself or the cutout fuse-holder in which they are installed. This capacity is for special loading situations such as short-time overloads and cold-load pick-up. All GK fuse links are precision manufactured and all materials are under control during manufacture to guarantee their quality. The GK fuse links are made for used with Fuse Cutout for protection medium voltage equipment. PRODUCT DETAIL Type K fuse links provide fast time-current characteristics. Type T fuse links provide slower time-current characteristics than the Type K. GK Type K and Type T fuse links are available with a standard removable button head or optional solid button head. Overall length of fuse links shall be 26 inches (approximate 660 mm) for rating voltage 27 kV and 30 inches (approximate 760 mm) for rating voltage 38 kV. Other lengths are also available upon request. Type K Catalog Number
Type T Catalog Number
Current Rating (Ampere)
27 kV
38 kV
27 kV
38 kV
1
271
381
T271
T381
2
272
382
T272
T382
Gunkul Engineering Public Co., Ltd 1038 -1046 Nakornchaisri Rd., Nakornchaisri, Dusit, Bangkok 10300, Thailand. Tel (662) 242 5800 (Auto) Fax (662) 242 5818-9, 242 5832-3 Email:
[email protected]
Type K Catalog Number
Type T Catalog Number
Current Rating (Ampere)
27 kV
38 kV
27 kV
38 kV
3
273
383
T273
T383
6
276
386
T276
T386
8
278
388
T278
T388
10
2710
3810
T2710
T3810
15
2715
3815
T2715
T3815
20
2720
3820
-
-
25
2725
3825
T2725
T3825
30
2730
3830
T2730
T3830
40
2740
3840
T2740
T3840
50
2750
3850
T2750
T3850
65
2765
3865
-
-
80
2780
3880
T2780
T3880
100
27100
38100
T27100
T38100
Gunkul Engineering Public Co., Ltd 1038 -1046 Nakornchaisri Rd., Nakornchaisri, Dusit, Bangkok 10300, Thailand. Tel (662) 242 5800 (Auto) Fax (662) 242 5818-9, 242 5832-3 Email:
[email protected]