Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
A self-contained system, the 7100 Series ARC® valve has a pressure reducing trim and is in-line repairable.
General Description The 7100 Series ARC® Valve has been specifically designed and manufactured to meet the demands and operating philosophies of today’s high pressure centrifugal pumps. Many power plants are now operating under peaking or throttled conditions, which in turn requires the pumps to operate at less than their optimal design and performance levels. As a result, they are subject to serious damage from hydraulic, mechanical and/or thermal abnormalities. The 7100 Series ARC® provides the most economical and reliable system to protect pumps from the dangers of low and/or reverse flow. It combines the functions of a check valve, flow sensing device, minimum flow control and pressure letdown into a single valve. The ARC® valve requires no external use of power and installs easily with only three connections. By eliminating at least seven major interdependent components, that ordinarily would be necessary to provide this protection, we have not only simplified the system, but made it much more reliable. Our quest for ensured pump flow protection does not, however, end at just providing the hardware. We analyze the complete pumping system and piping. Very often the application’s fluid hydraulics and dynamics compromise the effectiveness of the protection system. A thorough analysis of conditions up and downstream of both the pump and ARC® valve will provide us with solutions to “reliable” protection... things such as 1) proper pressure throughout the complete by piping to prevent any level of flashing or cavitation; (a condition that is prevalent in all pressure breakdown systems); 2) improved by manifold arrangements; 3) good piping layouts that promote stable operation; 4) stable and reliable interaction of pump and valve at less than optimal conditions of operation.
Flow Control
The 7100 Series ARC® is made to operate in a low flow condition for extended periods without damage to the valve or by piping system. The need is no longer just for emergency, short duration shut down, but for extended operation at low flows. Our check and by/pressure letdown elements are specifically designed to operate under these difficult conditions. There is no need
for an auxiliary manual by- system which only serves to negate the advantage of an automatic system. The design of the 7100 Series ARC® is the result of 27 years of experience and over nine thousand ARC® valves in service. And to help ensure every valve works properly, functional tests are performed and the valves are then certified for the application.
Yarway is either a trademark or ed trademark of Tyco International Services AG or its s in the United States and/or other countries. All other brand names, product names, or trademarks belong to their respective holders. Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418-US-0910
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
7100 Series ARC® (ANSI Class 900-1500) Features and Benefits Self-contained valve provides the functions of: Check valve, flow sensing element, by flow control valve and multi stage pressure letdown device.
Patented by flow control and pressure letdown system • Helps ensure fail safe operation and pump flow protection.
• Simplifies the system.
• Eliminates cavitation, flashing, choked flow and/or damage in by line.
• Reduces cost of Engineering, istration, Installation and Maintenance of complex, conventional flow control valve and instrument systems. • Eliminates requirement for external source of power and/or instrument signals. One valve replaces seven interdependent components • Eliminates multi vendor responsibility and coordination. • Enhances system reliability.
Complete in-line accessibility • Allows for adjustment, inspection and/or maintenance of all internals without removing the valve from the line or disrupting any piping. Field adjustability • Enables to change main flow, by flow and switch point. • Accommodates changes in pump operation. True by flow modulation • Help ensure proper minimum pump flow.
• Provides a smooth transition from main flow to by flow, thus eliminating piping shock. • Conserves energy. Valves are completely functional tested • Valve is certified correct for its application. • Helps ensure reliable performance from every valve.
One Valve – Four Functions • Check valve – prevents reverse flow. • Instrumentation – flow sensing and by activation. • By flow control – helps ensure minimum pump flow. • Pressure letdown – reduces pressure of fluid returning to its sources.
By activation and switchpoint adjustment
Check valve prevents reverse flow back into pump
Flow sensing element
By
Outlet
Inlet
By flow control Vortex flow development
Separate tight shut off sealing surfaces
By
Multi-stage pressure letdown
Piloted by piston positioning External by flow adjustment
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 2
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
ARC® system simplifies installation:
Control Loop System Storage vessel
• One piece to be installed Gate valve (optional)
• Only three connections Multiple pressurereducing orifice
• Eliminates at least seven welds • No electric or air supply lines to install • No instrumentation hook up or calibration
Four-way air solenoid valve
Recirculation control valve
• No special piping requirements
ARC®
system increases reliability:
FIC To process
Gate valve (optional)
• Specifically designed for fail safe operation • Fewer moving parts cuts down failure potential • No external source of power to jeopardize operation
Gate or control valve
Flow meter
Check valve Pump
Sensing orifice
• Single vendor responsibility
ARC® system eliminates: • Sensing orifice • Instrumentation • Air/electric supply
Yarway System Remote back pressure regulator (optional)
• Check valve
Storage vessel
• By flow control valve • Pressure letdown valve
ARC® reduces maintenance:
Check valve To process
• All internals are in-line accessible • Wear points such as levers and linkages are eliminated
By element
• No external source of power required • Actuators and controls are eliminated • No calibration required • No dynamic seals or packing
Gate or control valve
Automatic recirculation valve
Pump
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 3
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
7100 Series – Butt Weld Ends A
H H
B B
JJ
G G Min. clearance clearance Min. to remove remove to bonnet/disc bonnet/disc assembly assembly
D D Valve Valve inlet inlet
C
By By connection connection far far side side
By By discharge discharge F F Min.clearance clearanceto Min. remove cascade to remove bushing cascade bushing
E E
7100 Series – Flanged Ends A A
H
B
JJ G G Min. clearance Min. clearance remove to remove bonnet/disc bonnet/disc assembly assembly
D D Valve Valve inlet inlet
C
By By connection connection far far side side
By By discharge discharge FF Min.clearance clearance Min. to to remove remove cascade bushing cascade bushing
E E
RF RFflanged flanged end per per end ANSI B16.5 B16/5 ANSI
Dimensions and Weights for Class 900 and 1500 Valves, inches [mm] Valve Size
By Conn.
A
B
C
3" [80] 4" [100] 6" [150] 8" [200]
11/2"
201/2
8 11/16
11 3/32
[40] 2" [50] 21/2" [65] 3" [80]
[520.7] 251/2 [647.7] 36 [914.4] 42 [1066.8]
[220.7] 11 [279.4] 15 5/8 [396.9] 18 1/4 [463.6]
[35.7] 13/4 [44.5] 2 3/8 [60.3] 3 [76.2]
D 8 [203.2] 11 [279.4] 14 [355.6] 18 [457.2]
E 10 [254] 14 [355.6] 20 [508] 24 [609.6]
F 18 [457.2] 24 [609.6] 34 [893.6] 41 [1041.4]
G
H
J
12 [304.8] 15 [381] 21 [533.4] 28 [711.2]
13 1/2
7 1/2 [190.5] 9 1/2 [241.3] 12 [304.8] 15 [381]
[342.9] 17 [431.8] 22 1/2 [571.5] 28 [711.2]
Nominal Weight Butt Weld Flanged lb. (kg) 260 (118) 500 (227) 1450 (658) 2650 (1202)
360 (163) 640 (290) 1725 (782) 3150 (1429)
Dimensions are the same for Flanged and Butt Weld end valves. Available in DIN and JIS end connections. Valve size and by connection – in., [DN]; Dimensions – in., [mm]; Weight – lb., (kg).
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 4
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
Sizing Guide Valve Size
3"
4"
6"
8"
Main Flow Range
120-400 GPM 27-91 M3/hr
300-715 GPM 68-162 M3/hr
600-1575 GPM 136-358 M3/hr
700-2675 GPM 159-608 M3/hr
0.3-0.4 (0.26-3.5Kv) 0.2-2.0 (0.17-1.7Kv)
1.0-11.5 (0.87-9.9Kv) 0.8-8.0 (0.69-6.9Kv)
3.0-24.0 (2.6-20.8Kv) 2.0-17.0 (1.7-14.7Kv)
5.0-40.0 (4.3-34.6Kv) 4.0-28.0 (3.5-24.3Kv)
By Cv Range 2 Stage1 4 Stage2 1) For DPs up to 1500 psid
2) For DPs between 1500 and 3000 psid
Pressure and Temperature Selector Guide Model No.
Butt Weld Flanged
7105 7106
7107 7108
900
1500
ANSI Pressure Class Temperature
Working Pressures (psig)
100°F 200°F 300°F 400°F 500°F
2220 2025 1970 1900 1795
3705 3375 3280 3170 2995
Notes: 1. Determine pressure class and model no. by consulting pressure and temperature selector guide above. 2. To select valve size: refer to ARC® sizing guide above. Be sure normal and maximum pump operation flows fall within the flow range noted for the given valve. 3. that by capacity meets minimum pump flow requirement:
Q min DP S.G. Minimum pump flow
Calculate Cv: Q min =
Installation
Valve Installation (common line to receiver)
Receiver vessel
DP
=
S.G.
=
{
=
Pump discharge pressure minus by line pressure Specific gravity of fluid pumped
Piping Installation (separate line to receiver)
Receiver vessel
Recommended location of back pressure orifice or back pressure regulator when specified By outlet Block valve By outlet
Check valve
Check valve
Long radius type pipe bends
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 5
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
50, 50, 49 49
7
33 33
44
88
See detail DetailAA
66
17
3
2 2
11 Per ANSI B16.5 Per B16.5 5
51 51 51 51 See See detail DetailBB
46 46 See Seesectional sectional Detail C forilot Detail for valvepilot representation valve
47 47
representation 18
13 13
32 32
15 19 48 48
52 52
58 58
59 12 12
30 27
53
26 26
29 29
51
14 14
31
22 22 11 11
10 10
9
7 56 56
55 55
57 57 23 23 34 34
Detail B Detail B Detail A Detail A
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 6
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
Detail C Detail C
4242
Notes: 1. Recommended spare parts for service inspection.
4343
3838
2. Recommended spare parts for service overhaul.
2222 4444
3. Optional on body.
1919
4141 3939
4848 2828
4545 3636
2727
3535 6060
Parts and Materials Item
Part
Material
Specification
Item
Part
Material
Specification
1
Body
Cast Steel
2
Bonnet
Cast Steel
3
SS
SS
Type 17-7 PH
6
Pipe Plug Segmented Retaining Ring Segmented Ring Retainer Spring
ASME SA216 Gr. WCB DIN 17245–Material No.1.0619 GS-C-25 Type 316 ASME A487 Gr. CA6NMCL. A
SS
7
Disc
SS SS SS SS Elastomer SS
ASTM A105 ASME SA193 Gr. B7 ASME SA194 Gr. 2H TFE Propylene TFE Propylene TFE Propylene TFE Propylene TFE Propylene TFE Propylene TFE Propylene ASTM A276 Gr. 440C TFE Propylene Type 431
SS
Type 431
Elastomer
SS SS
Elastomer Elastomer SS SS
TFE Propylene Carbon/graphite reinforced PTFE TFE Propylene TFE Propylene Type 18-8 Type 302
18 2
By Bushing
SS
SS
Type 316
19 2
Piston
SS
Alloy Steel
ASME SA 193 Gr. B7 ASTM A105
Pilot Tube
23 1,2 26
Metering Orifice Spring Pin Stroke Adjustment Screw Spring Pin Lock Nut
SS and Stellite SS SS
CS
221,2
Elastomer Gasket
TFE Propylene Reinforced Teflon®
SS
Type 316
SS
ASME SA564 Gr. 630
SS SS
Type 18-8 Type 18-8
By Cover Stud Nut O-ring O-ring O-ring O-ring O-ring O-ring Seal Assembly Anti-Rotation Key Retainer (O-ring) Pilot Valve Seat Pilot Tube Seal Plug O-ring Back-up Ring (3" Valve Only) O-ring O-ring Drive Screws Nameplate Pipe Plug (Pressure Tap) Stud Stroke Adjustment Screw Cover Filter Gasket, Lower Filter Gasket, Upper Filter Housing and Screen Assembly Retaining Ring Seal Assembly Retaining Ring
CS Alloy Steel Alloy Steel Elastomer Elastomer Elastomer Elastomer Elastomer Elastomer Elastomer SS Elastomer SS
15 17
Orifice Snubber Retaining Ring Washer Seal Assembly Disc Lower Guide Bushing Switch Point Adjustment Screw Switch Point Adj. Screw Bushing Spring Pin (Bushing) Flow Element
Type 17-7 PH ASME SA351 Gr. CF8M Type 316 PH 15-7 Mo ASTM A276-XM19 TFE and SS ASTM A479 Type XM19 ASTM A582 Type 416 ASTM A582 Type 416 Type 18-8 Type 316 ASTM A747 Gr. CB7 Cu-1 ASME SA479 Type 410 ASME SA564 Gr. 630 w/ Stellite 6 seat Type 431 Type 18-8
30 31 32 33 1,2 34 1,2 35 1,2 36 1,2 38 1,2 39 1,2 41 1,2 42 1,2 43 1,2 44 1,2
SS Elastomer SS
Type 17-7 PH TFE Propylene PH 15-7 Mo
4 5
8 9 10 111,2 12 13 14
27 28 29
SS
SS SS
45 2 46 1,2 46a1,2 47 1,2 48 1,2 49 50 513 52 53 551,2 561,2 57 58 59 1,2 60 2
Copyright © 2009 Tyco Flow Control. All rights reserved.
Elastomer
YAWMC-0418 7
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
Back Pressure Regulator (BPR) line is reduced, the orifice becomes less effective. Proper system design should be used to optimize valve pressure reduction and consider all fluid dynamic effects downstream of any pressure reducing device.
In high pressure pumping applications the system often does not provide adequate pressure in the by line to prevent cavitation or flashing. Either of these conditions is undesirable in that it can cause damage to both valves and the pipe system or cause a reduction in flow beyond the minimum desired, jeopardizing the pump protection system. All PRVs will experience a velocity induced recovery effect which will limit the amount of pressure drop a valve can take and cause a reduction in flow capacity.
When adequate back pressure is not available downstream of a pressure reducing valve, vapor bubbles will form in the zone just downstream of the valve last stage control surface. This zone is defined as the “Vena Contracta” and represents the point of highest fluid velocity and lowest pressure. The potential for 1) damage to downstream piping components and 2) flow reduction exists from this point. When line pressure remains below the fluid vapor pressure, any existing bubbles will remain and expand as piping friction further reduces line pressure. This can be defined as a “FLASHING CONDITION” and is characterized by a polished appearance on affected surfaces. When the line pressure drops below the fluid
The requirement of back pressure is generic to all pressure reducing applications. Pressure reduction even by multiple stage cascading such as in the 7100 Series ARC® can minimize the requirement, however no valve design will redefine a fluid’s physical properties. This becomes especially important in modulating systems. A fixed orifice will not provide the proper back pressure at all flow levels. As the flow in the by
vapor pressure and then recovers, any entrapped vapor bubbles will collapse (implode). This is defined as a “CAVITATING CONDITION” and is characterized by a cinder like appearance on affected surfaces. The resolution of either condition is best addressed by eliminating vapor formation. This can be ensured by the provision of adequate back pressure. The “Backpressure Factor” is key to reliable system operation and must not be ignored in piping design considerations. As such we feel it is the obligation of a responsible Automatic Recirculation Control Valve manufacturer to analyze the system needs and supply a Back Pressure Regulator (BPR) when it is warranted by the laws of fluid dynamics. For on/off systems this could be a simple orifice, but for modulating conditions it must be a device like the BPR noted herein.
Flanged body BPR illustrated (installed between flanges). Wafer BPR is also available.
Yarway 7100 ARC® Valve
Inlet By outlet
Flow Check valve
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 8
Back pressure regulator
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
Back Pressure Regulator (BPR) Wafer BPR – 3/4" to 6"
Remote Mounted Flange BPR – 11/2" to 10" 98
2
7
10 10
4
11 11
3
22
10 10
77
1
12, 13 13 12,
55
9 9
Flow Flow
Flow Flow
ØøA A
6
1 1
12 12
5
8 8
11 11
13 13
66
3 3
44
9 9
B C
Parts and Materials
Parts and Materials Item
Part
Material
1 2 3 4
Body Seat Plunger Guide O-ring
5
Plunger
6
Spring Retainer
ASME SA105 ASTM A747-CB7Cu-1 with Heat Treatment ASTM A276-S21800 (Nitronic 60 Bar) TFE/P (Fluoraz 799) AISI 431 Stainless Steel with Heat Treatment AISI 304 Stainless Steel ASTM A564 Type 631 (17-7 PH) H-900 Heat Treatment
7 8 9 10 11 12 13
Spring Energized “U” Cup Seal Retaining Ring Nameplate Drive Screw Spacer Spiral Ring
Filled TFE AISI 304 Stainless Steel AISI 300 Series Stainless Steel Stainless Steel A269-304 Inconel® X-750
Item
Part
Material
1 2
Body Seat
3
Plunger Guide
ASME SA105 ASTM A747-CB7Cu-1 with Heat Treatment ASME SA564 Type 630 (17-4 PH) H-900 Heat Treatment
4
Energized “U” Cup Seal
5 6 7 8 9 10 11 12 13
Filled TFE
ASTM A479-431 Stainless Steel with Heat Treatment ASTM A564 Type 631 (17-7 PH) H-900 Spring Heat Treatment Spring Retainer AISI 304 Stainless Steel Spiral Ring AISI 302 Flow Conditioner ASME SA747-CB7Cu-1 Retaining Ring AISI 316 Stainless Steel Set Screw ASTM A194 Grade 8 (18-8) Nameplate AISI 300 Series Stainless Steel Drive Screw Stainless Steel Plunger
Option: BPR is available in stainless steel configuration upon request.
Dimensions and Weights A
Dimensions, in. [mm] B Flanged C
BPR Size
+/- 1/16" [1.6]
+/- 1/16" [1.6]
+/- 1/16" [1.6]
3/4" 11/2" 2" 3" 4" 6"
11/6 [42.9] 2 7/8 [73.0] 3 5/8 [92.1] 5 [127.0] 6 3/16 [157.2] 8 1/2 [215.9]
4 2 7/8 3 3/8 4 5/8 5 3/4 7 1/2
6 6 8 12 17
[101.6] [73.0] [85.7] [117.5] [146.0] [190.5]
N/A [152.4] [152.4] [203.2] [304.8] [431.8]
Wafer Approx. Weight lb. (kg) 5 (2.3) 5 (2.3) 8 (3.6) 21 (9.5) 40 (18.1) 96 (43.5)
For Flanged 8" and 10", your sales representative. Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 9
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
Hydraulic Performance Test Lab
Performance – Profiled in Yarway’s Hydraulic Performance Test Lab In our hydraulic performance test laboratory, state-of-the-art data acquisition and computer graphics techniques are called upon for evaluation of the significant performance characteristics of Yarway recirculation control valves. The lab’s equipment makes it possible to test a valve over its complete flow range for factors including:
• Total flow through the pump • Disc position • Pressure drop across the main check • By Cv • By DP • Valve response to sudden changes in flow • By piston pressure These detailed analyses are the ’s complete assurance that the valve meets performance requirements in all respects and can be supplied with the valve. A certified test curve is shipped with each valve (see page 11 for example). Insist on it, as you would for your pump!
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 10
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
Certified Test Curve Main (GPM) 0 0
200 200
400 400
600 600
800 800
1000 1000
1200 1200
1400 1400
1600 1600
1800 1800
0 0
200 200
400 400
600 600
800 800
1000 1000
1200 1200
1400 1400
1600 1600
1800 1800
Main DP (PSID)
25.0 20.0 15.0 10.0 5.0
10.0 9.0 8.0 8 0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0
120 100 80 60 40 20
Piston Pressure (PSIG) - - - - -
By Cv
Disc Lift (IN)
0.0 2.00 1.80 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00
0 0
200
400
600
800
1000
1200
1400
1600
1800
Main (GPM) 1800
1600
Total Flow (GPM)
1400
1200
1000
800
600
400
200
0 0
200
400
600
800
1000
1200
1400
1600
1800
Main Flow (GPM)
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 11
Yarway 7100 Series ARC® Valve For Centrifugal Pump Protection
How to Order Our sales representatives will help you select the correct valve for your application. Please complete this form before ing the sales office to help ensure all necessary information is provided.
Automatic Recirculating Control (ARC®) Valve Data Sheet Customer: Company: Project: Location: Phone:
E-Mail:
Qty Required:
Delivery Required:
Additional Info:
Tag(s) ID:
Pump Flow
Please Complete Flow Requirements Normal -Process- flow:
M3/H
GPM
BPD
Maximum -Process- flow: Minimum -Process- flow (optional):
(if Minimum Flow is to be considered in sizing)
Minimum pump protection flow:
Pump Discharge Pressure
(Minimum required “Recirculation Flow”) Please Complete Pressure Requirements
Pump pressure at Shut-off (zero flow):
psi
KgF/cm2
bar
Kpa
Pump pressure at Normal -Process- flow: (if Minimum Flow is to be considered in sizing)
Pump pressure at Minimum -Process- flow (optional):
(at Minimum required “Recirculation Flow”)
Pump pressure at Minimum pump protection flow:
(Line pressure at ARC Valve by port)
ARC Valve By line pressure:
Temperature
Please Enter Both Temperatures °F
Normal temperature at ARC Valve:
°C
Maximum temperature at ARC Valve:
Fluid Liquid: Boiler Feed Water (In this case disregard S.G. and V.P.) Other (Please specify) _________________ Specific Gravity:
Orientation of ARC Valve:
Vapor Pressure:
Desired End Connections:
Viscosity:
Desired Pressure Class: Desired Body Material:
Desired Seal Material (except 2" to 8" 9200 and 9300):
Pump Drive Type:
Vertical
Horizontal
Raised Face Flange Ring Type t (RTJ) Flat Face Flange Butt Weld Ends Other - Specify in “Comments” 150
300
600
900
1500
2500
A216 Gr. WCB A351 Gr. CF8M A351 Gr. CK3MCuN (6Mo) A995 Gr. CD3MWCuN (Super Duplex) Ethylene Propylene (EPR or EPDM) TFE Propylene (Aflas or Fluoraz) Fluorocarbon Rubber (Viton®) Other - Specify in “Comments” Constant Speed - Motor Driven Variable Speed (VFD) - Motor Driven Variable Speed - Turbine Driven Other - Specify in “Comments”
Comments:
NACE Materials Required?
Certificate of Compliance for Hydro Test Required?
Flow Test with Performance Certificate Required?
Magnetic Particle Test Required?
Customer Inspection Required Prior to Shipment?
Radiograph Inspection Required (specify scope)?
Certified Material Test Report (Pressure Containing Components only)?
Flow tests are generally conducted on all model 5300 and 7100 ARC® valves and one model 9100 or 9200 ARC® valve per sales order line item at no additional cost. Model 9300 ARC® valves and other flow test requirements are upon request and at additional cost. If flange drilling is other than ANSI, please specify in “Comments.” Please include Pump Curve if available. Tyco Flow Control (TFC) provides the information herein in good faith but makes no representation as to its comprehensiveness or accuracy. This data sheet is intended only as a guide to TFC products and services. Individuals using this data sheet must exercise their independent judgment in evaluating product selection and determining product appropriateness for their particular purpose and system requirements. TFC MAKES NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE INFORMATION SET FORTH HEREIN OR THE PRODUCT(S) TO WHICH THE INFORMATION REFERS. ACCORDINGLY, TFC WILL NOT BE RESPONSIBLE FOR DAMAGES (OF ANY KIND OR NATURE, INCLUDING INCIDENTAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES) RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. Patents and Patents Pending in the U.S.and foreign countries. Tyco reserves the right to change product designs and specifications without notice. All ed trademarks are the property of their respective owners. Printed in the USA.
Copyright © 2009 Tyco Flow Control. All rights reserved.
YAWMC-0418 12
www.tycoflowcontrol.com