Manual for DM800 ECDIS hardware Document Number 9301582 Version Number 1.1 Date November 2012
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
Revision record Version 1.0 1.1
9301582-11
Date May 2010 November 2012
Description Original issue of document Updated to reflect ECDIS software version 1.50
Page 2/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
Contents REVISION RECORD ...........................................................................................................2 1 1.1 1.2
SCOPE AND PURPOSE ..........................................................................................4 References................................................................................................................4 and Abbreviations ..........................................................................................4
2 SYSTEM OVERVIEW FOR DM800E........................................................................5 2.1 System overview .......................................................................................................5 2.1.1 DPU (Data Processing unit) ...............................................................................6 2.1.2 DVD drive and External USB port ......................................................................6 2.1.3 eToken...............................................................................................................6 2.1.4 RPU (Radar processing unit) .............................................................................6 2.1.5 Alarm ........................................................................................................6 2.2 ECDIS cluster............................................................................................................7 3 3.1 3.2 3.3
ALARM ........................................................................................................8 Alarm volume ............................................................................................................8 ECDIS computer shut down ......................................................................................8 ECDIS computer restart ............................................................................................8
4 4.1 4.2
MONITOR .................................................................................................................9 Control on monitor...........................................................................................9 Control of Monitor......................................................................................................9
5 5.1 5.2
SELF TEST.............................................................................................................10 Buzzer in alarm .............................................................................................10 Test of monitor ........................................................................................................10
6 ECDIS DATA PROCESSING UNIT (DPU) .............................................................11 6.1 AC breaker..............................................................................................................11 6.2 Status LEDs ............................................................................................................12 6.2.1 U status LED...............................................................................................12 6.2.2 FE status LED..................................................................................................12 7 SYSTEM MANAGEMENT .........................................................................13 7.1 System Management ....................................................................................14 7.2 Initialization of an eToken .......................................................................................15 7.2.1 When to perform an eToken initialization .........................................................15 7.2.2 Performing an initialization of a new eToken....................................................15 7.2.3 Performing a reinitialization of an existing eToken...........................................17 7.3 Dump for ....................................................................................................19
9301582-11
Page 3/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
1 Scope and purpose manual for DM800E ECDIS
1.1 References 9301584
Manual for Dolphin ECDIS
1.2 and Abbreviations ECDIS
9301582-11
Electronic Chart Display and Information System
Page 4/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
2 System overview for DM800E 2.1 System overview One ECDIS consists of the following parts:
Display
Alarm
Keyboard
DVD drive and External USB port DVD drive
USB port
DVI COM1 USB 6
USB 7
ECDIS DM800 DPU
USB 5
AP eToken USB 8 USB 2
RPU (optional)
4x 2 x IEC 10 x IEC Ethernet 61162-2 61162-1 To other For sensors ECDISs
9301582-11
Radar
Page 5/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
2.1.1 DPU (Data Processing unit) The data processing unit contains the computer for the ECDIS application and a communication front-end. The DPU is installed in the main cabinet. For more information consult section 6.
2.1.2 DVD drive and External USB port The DVD drive and external USB port is installed in the main cabinet. These are used for updating charts and software. Notice, charts can be updated using the Internet.
2.1.3 eToken The eToken contains the keys needed for enabling access to charts. The eTokens for one installation (i.e. vessel/cluster) shall be regarded as at set and must not be mixed with eTokens from another installation.
2.1.4 RPU (Radar processing unit) The RPU is an optionally interface to the vessels radar. When installed, radar overlay on the charts can be displayed. The RPU is installed in the main cabinet.
2.1.5 Alarm The ECDIS alarm is a small box that must be installed adjacent to the monitor. Consult section 3
9301582-11
Page 6/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
2.2 ECDIS cluster A complete ECDIS installation will in most cases consist of a number of systems (a cluster). In order to ensure redundancy each ECDIS must be connected to two other systems if the cluster contains more than two systems. Master
12
Backup
12 Cluster containing two ECDISs
Master
12
Backup
12
Planning
12
Cluster with three ECDISs
9301582-11
Page 7/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
3 Alarm
The ECDIS alarm is a small box adjacent to the monitor.
3.1 Alarm volume The ECDIS will generate an audible alarm following an error e.g. if the signal from the GPS is lost. The volume of the alarm signal may be adjusted pressing the buttons marked “Alarm volume”.
3.2 ECDIS computer shut down Notice! The procedure described in this section is only applicable if the ECDIS application freezes or stops responding to input. The normal procedure for closing the ECDIS application (i.e. setting the ECDIS standby) is to click on in the right top corner. Press the two reset buttons simultaneously for approximately 5 seconds in order to shut down the computer for the ECDIS application.
3.3 ECDIS computer restart Press the two buttons simultaneously in order to restart the computer. This is applicable both after a “hard” shutdown (see section 3.2) or if the ECDIS is standby after the application is closed normally.
9301582-11
Page 8/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
4 Monitor 4.1 Control on monitor Under normal operating conditions do not change the monitor settings except for brightness which is controlled by the adjusting knob. Please notice that the monitor is not calibrated unless the white line on the knob is facing up (12 o’clock). The monitor can be reset to calibrated state (expect for brightness control) by reverting to factory settings (consult the manual for the monitor).
4.2 Control of Monitor The color generating capability of the monitor may deteriorate over time. How the quality of the monitor is checked is described in p/n 9301584 “ Manual for Dolphin ECDIS” in the section named “Color Differentiation Test”.
9301582-11
Page 9/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
5 Self test The presence of the DVD drive, keyboard, Trackball, eToken and optionally the RPU is checked by the DPU. An alarm will be generated if an error on one of these devices is detected.
5.1 Buzzer in alarm The buzzer in the alarm may be checked by pressing volume up or down. The alarm will sound shortly at the current audio level if one of the buttons is pressed shortly.
5.2 Test of monitor Check the colors and the contrast for the monitor (visual), if in doubt consult section 4.2.
9301582-11
Page 10/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
6 ECDIS data processing unit (DPU) DPU front :
6.1 AC breaker The ECDIS DPU is protected by electronic circuits and a resettable breaker. The breaker will pop out if one of the following events happens Over voltage Permanent under voltage Excessive input current Internal power supply failure It is safe to push the breaker in if popped out (if it pops out right away wait at least one minute before pushing it in aging)
9301582-11
Page 11/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
6.2 Status LEDs 6.2.1 U status LED Off: The computer for the ECDIS application is standby or without power. If the “FE status LED” is turned off then check the power breaker (must be pressed in). After this check the presence of power. Green (normal operation): The computer for the ECDIS application is powered on and is probably operating normally. Blue flash (normal operation): Disk activity. Green blinking (1Hz): Error on DVD drive, keyboard or Trackball. Red/yellow: The computer for the ECDIS application did not start.
6.2.2 FE status LED Off: The AC power is not present or the AC breaker is disconnected (popped out). Green (normal operation): The FE is started and has detected that the computer for the ECDIS application is responding. Red: Booting (not ready). If the Red LED is turned on for more than 60 second, close the application normally. If this is not possible use the alarm (se section 3.2). After that, restart the ECDIS by switching the AC power off and on (operate the AC breaker next to the AC input plug). Blue: The computer for the ECDIS application is not responding. Switch the power off and then on (operate the AC breaker) if this condition remains for more that 6 minutes.
9301582-11
Page 12/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
7 System Management The ECDIS includes a System Management for performing special non standard tasks. Notice: The System Management should be used only by personal with prober authorization, as incorrect use may result in loss of chart licenses. The System Management is opened from ECDIS application. Move the cursor to the right bottom corner on the chart and this box will appear.
Click on Config
Select the system tab and click on “System Management” You will be prompted for a The default is: system manager
9301582-11
Page 13/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
7.1 System Management
Notice: Double click on the icons to execute the programs. • Reset Licenses: This is needed if a new eToken is installed, consult section 7.2 (Requires restart) • Restart ECDIS (application) • Change : Change the System Management . • Dump For : Create a Dump For file. This may be requested by the service technician in case of problems with the system. Please consult section 7.3 • Restart: ECDIS computer restart - this will not affect the front-end. • Shutdown: ECDIS computer shutdown - this will not affect the front-end. Use the [ X ] to close the .
9301582-11
Page 14/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
7.2 Initialization of an eToken 7.2.1 When to perform an eToken initialization An initialization is a pairing between the DPU and the eToken. Only one eToken can be initialized on a DPU at a time, so initializing an eToken automatically removes the initialization of a previous eToken. An initialization is always required if an eToken is replaced with another eToken, or if an eToken is moved to another DPU. An eToken can be initialized an unlimited number of times. Please notice, the ECDIS application will not accept sensor data unless an eToken has been initialized on the system.
7.2.2 Performing an initialization of a new eToken Use this feature to initialize a new eToken and when replacing an existing eToken on a system. After double clicking Reset Licenses on the System Management , the ECDIS will restart and after approximately 1 minute the following image may be shown (the image will be skipped if the attached eToken is not the currently initialized eToken).
Click on “No”.
Insert the new eToken for the ECDIS in USB port 8 on the DPU. Click on “OK”.
9301582-11
Page 15/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
The system may install a driver depending on the type of eToken you have inserted. A driver installation involves several restarts.
The system displays this message when finished:
Click on “Yes”. (The driver is already installed).
Click on “Yes”.
Click on “Yes”. After a few second the eToken has been initialized.
9301582-11
Page 16/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
Click on “OK”.
Click on “OK” to restart the ECDIS and return to normal operation.
7.2.3 Performing a reinitialization of an existing eToken Use this feature to reset the licenses for an already initialized eToken. Make sure the eToken is inserted in USB port 8 on the DPU. After double clicking Reset Licenses on the System Management , the ECDIS will restart and after approximately 1 minute the following image will be shown:
Click on “Yes”.
Click on “Yes”. (The driver is already installed)
Click on “Yes”.
9301582-11
Page 17/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
Click on “Yes”. After a few second the eToken has been reinitialized.
Click on “OK”.
Click on “OK” to restart the ECDIS and return to normal operation.
9301582-11
Page 18/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
7.3 Dump for Utilize this feature if help for troubleshooting is needed.
Insert a USB stick in the USB port adjacent to the DVD drive Click “Browse” and select the USB stick as destination i.e. typically drive E: Use the filename suggested by the program.
Click on “Save”
Click on “Start dump”
9301582-11
Page 19/20
manual for DM800E ECDIS hardware Copyright Danelec Marine A/S
This window will open and the progress will be displayed
Click on “Close”
9301582-11
Page 20/20